All Portions of Conveyor Belt Running to One Side at a Given Point on Structure

CAUSECORRECTION
Belt too stiff to train.1. Use self-aligning idlers.
2. Increase tension.
3. Use more flexible belt on replacement.
4. Tilt troughing idlers forward but not over 2°.
Combination of causes1. Correct loading first.
2. Other causes can be identified and corrected by referring to preceding monograph.